การออกแบบฟลูอิไดซ์เบดแบบหมุนเวียน: ผลของลักษณะแอลวาล์วในการไหลที่อุณหภูมิห้อง

In this research, L-valve was used in the circulating fluidized bed to control solid circulation rate. The effect of L-valve configuration in cold-flow (the position of aeration tap, angle of L-valve, solid inventory and aeration flow rate) was studied by measuring the solid circulation rate. Coal w...

Full description

Saved in:
Bibliographic Details
Main Author: พีรพล ฐิติอนันท์
Other Authors: เลอสรวง เมฆสุต
Format: Theses and Dissertations
Language:Thai
Published: จุฬาลงกรณ์มหาวิทยาลัย 2002
Subjects:
Online Access:https://digiverse.chula.ac.th/Info/item/dc:35751
Tags: Add Tag
No Tags, Be the first to tag this record!
Institution: Chulalongkorn University
Language: Thai
Description
Summary:In this research, L-valve was used in the circulating fluidized bed to control solid circulation rate. The effect of L-valve configuration in cold-flow (the position of aeration tap, angle of L-valve, solid inventory and aeration flow rate) was studied by measuring the solid circulation rate. Coal which has the density of 1381 kg/m[superscript 3], particle size distribution between 500 and 5000 micron, average particle size of 740 micron and was categorized in group B and D in Geldart s classification was used. From this study, solid circulation rate at the position of 6 cm above the center of horizontal L-valve was higher than the position of 0 and 12 cm only when horizontal L-valve. The solid circulation rate was increased when aeration flow rate and angle of L-valve increased and it didn t depend on the solid inventory. Finally, the relationship between the solid circulation rate and these parameter was studied.