A prospective assessment of the accuracy of commercial IgM ELISAs in diagnosis of Japanese encephalitis virus infections in patients with suspected central nervous system infections in Laos

Japanese encephalitis virus (JEV) is a major cause of encephalitis in Asia. We estimated the diagnostic accuracy of two anti-JEV immunoglobulin M (IgM) enzyme-linked immunosorbent assays (ELISAs) (Panbio and XCyton JEVCheX) compared with a reference standard (AFRIMS JEV MAC ELISA) in a prospective s...

全面介紹

Saved in:
書目詳細資料
Main Authors: Catrin E. Moore, Stuart D. Blacksell, Thaksinaporn Taojaikong, Richard G. Jarman, Robert V. Gibbons, Sue J. Lee, Vilada Chansamouth, Soulignasack Thongpaseuth, Mayfong Mayxay, Paul N. Newton
其他作者: Mahosot Hospital
格式: Article
出版: 2018
主題:
在線閱讀:https://repository.li.mahidol.ac.th/handle/123456789/14297
標簽: 添加標簽
沒有標簽, 成為第一個標記此記錄!
機構: Mahidol University
實物特徵
總結:Japanese encephalitis virus (JEV) is a major cause of encephalitis in Asia. We estimated the diagnostic accuracy of two anti-JEV immunoglobulin M (IgM) enzyme-linked immunosorbent assays (ELISAs) (Panbio and XCyton JEVCheX) compared with a reference standard (AFRIMS JEV MAC ELISA) in a prospective study of the causes of central nervous system infections in Laos. Cerebrospinal fluid (CSF; 515 patients) and serum samples (182 patients) from those admitted to Mahosot Hospital, Vientiane, were tested. The CSF from 14.5% of acute encephalitis syndrome (AES) patients and 10.1% from those with AES and meningitis were positive for anti-JEV IgM in the reference ELISA. The sensitivities for CSF were 65.4%(95%confidence interval [CI] = 51-78) (Xcyton), 69.2% (95%CI = 55-81) (Panb io), however 96.2% (95% CI = 87-100) with Panbio Ravi criteria. Specificities were 89-100%. For admission sera from AES patients, sensitivities and specificities of the Panbio ELISA were 85.7% (95% CI = 42-100%) and 92.9% (95% CI = 83-98%), respectively. Copyright © 2012 by The American Society of Tropical Medicine and Hygiene.