UNJUK KERJA MOTOR INDUKSI ROTOR LILIT SEBAGAI VARIABEL-TRANSFORMATOR
Generally induction motor is used as a tool to change electric power to mechanic one. In forced condition wound-rotor induction motor can be used as transformer. This case can be accepted for both machines work by induction principle. Stator is the primary side of a three phase-tra...
Saved in:
Main Authors: | , |
---|---|
格式: | Article PeerReviewed |
語言: | English |
出版: |
Jurusan Teknik Informatika Fakultas Teknologi Industri UPN "Veteran" Jogjakarta
2009
|
主題: | |
在線閱讀: | https://repository.ugm.ac.id/35942/1/4_Unjuk_Kerja_Motor_Induksi_Rotor_Lilit_Sebagai_Variabel-Transformator.pdf https://repository.ugm.ac.id/35942/ |
標簽: |
添加標簽
沒有標簽, 成為第一個標記此記錄!
|
id |
id-ugm-repo.35942 |
---|---|
record_format |
dspace |
spelling |
id-ugm-repo.359422014-04-29T04:41:20Z https://repository.ugm.ac.id/35942/ UNJUK KERJA MOTOR INDUKSI ROTOR LILIT SEBAGAI VARIABEL-TRANSFORMATOR Subekti, Lukman Budiyanto, Ma'un Makalah prosiding Generally induction motor is used as a tool to change electric power to mechanic one. In forced condition wound-rotor induction motor can be used as transformer. This case can be accepted for both machines work by induction principle. Stator is the primary side of a three phase-transformer. Magnetic field produced by stator cuts across rotor conduction. This induction voltage cases the rotor current to flow. However, induction motor is one of non-linear load and be able to cause harmonic in alternating current. The objective of this research is to acknowledge the work of wound-rotor induction motor when its function is changed into a transformer. The research was done by the wound rotor supplied sinusoidal voltage as the primary of a three phase transformer. The magnetic filed produced by rotor cuts across stator conductor. Rotor position was regulated from 0 degree,45 degree, 90 degree, 135, up to 360 degree. In stator winding, the amount of emf induced proportional to the rate of flux change and the number of its wound. The result of research shows that wound-rotor induction motor can be used as variable transformer. Voltage change obtained is about 8%. Voltage waved) form isdefect sinusoidal. The average value of Total Harmonic Distortion (THD) is 1.8% for displacement of rotor angle from 0 degree up to 360 degree Jurusan Teknik Informatika Fakultas Teknologi Industri UPN "Veteran" Jogjakarta 2009-05-23 Article PeerReviewed application/pdf en https://repository.ugm.ac.id/35942/1/4_Unjuk_Kerja_Motor_Induksi_Rotor_Lilit_Sebagai_Variabel-Transformator.pdf Subekti, Lukman and Budiyanto, Ma'un (2009) UNJUK KERJA MOTOR INDUKSI ROTOR LILIT SEBAGAI VARIABEL-TRANSFORMATOR. Prosiding Seminar Nasional Teknik Informatika e-Democracy : “ Dukungan e-Democracy dalam Meningkatkan Mutu Demokrasi di Indonesia”, di Jurusan Teknik Informatika Fakultas Teknologi Industri UPN "Veteran" Jogjakarta. B-58-B-66. ISSN 1979-2328 |
institution |
Universitas Gadjah Mada |
building |
UGM Library |
country |
Indonesia |
collection |
Repository Civitas UGM |
language |
English |
topic |
Makalah prosiding |
spellingShingle |
Makalah prosiding Subekti, Lukman Budiyanto, Ma'un UNJUK KERJA MOTOR INDUKSI ROTOR LILIT SEBAGAI VARIABEL-TRANSFORMATOR |
description |
Generally induction motor is used as a tool to change electric power to mechanic one. In forced condition wound-rotor induction motor can be used as transformer. This case can be accepted for both machines work by induction principle. Stator is the primary side of a three phase-transformer. Magnetic field produced by stator cuts across rotor conduction. This induction voltage cases the rotor current to flow. However, induction motor is one of non-linear load and be able to cause harmonic in alternating current.
The objective of this research is to acknowledge the work of wound-rotor induction motor when its function is
changed into a transformer.
The research was done by the wound rotor supplied sinusoidal voltage as the primary of a three phase transformer. The magnetic filed produced by rotor cuts across stator conductor. Rotor position was regulated
from 0 degree,45 degree, 90 degree, 135, up to 360 degree. In stator winding, the amount of emf induced proportional to the rate of flux change and the number of its wound.
The result of research shows that wound-rotor induction motor can be used as variable transformer. Voltage
change obtained is about 8%. Voltage waved) form isdefect sinusoidal. The average value of Total Harmonic
Distortion (THD) is 1.8% for displacement of rotor angle from 0 degree up to 360 degree |
format |
Article PeerReviewed |
author |
Subekti, Lukman Budiyanto, Ma'un |
author_facet |
Subekti, Lukman Budiyanto, Ma'un |
author_sort |
Subekti, Lukman |
title |
UNJUK KERJA MOTOR INDUKSI ROTOR LILIT SEBAGAI VARIABEL-TRANSFORMATOR |
title_short |
UNJUK KERJA MOTOR INDUKSI ROTOR LILIT SEBAGAI VARIABEL-TRANSFORMATOR |
title_full |
UNJUK KERJA MOTOR INDUKSI ROTOR LILIT SEBAGAI VARIABEL-TRANSFORMATOR |
title_fullStr |
UNJUK KERJA MOTOR INDUKSI ROTOR LILIT SEBAGAI VARIABEL-TRANSFORMATOR |
title_full_unstemmed |
UNJUK KERJA MOTOR INDUKSI ROTOR LILIT SEBAGAI VARIABEL-TRANSFORMATOR |
title_sort |
unjuk kerja motor induksi rotor lilit sebagai variabel-transformator |
publisher |
Jurusan Teknik Informatika Fakultas Teknologi Industri UPN "Veteran" Jogjakarta |
publishDate |
2009 |
url |
https://repository.ugm.ac.id/35942/1/4_Unjuk_Kerja_Motor_Induksi_Rotor_Lilit_Sebagai_Variabel-Transformator.pdf https://repository.ugm.ac.id/35942/ |
_version_ |
1681219464590262272 |