UNJUK KERJA MOTOR INDUKSI ROTOR LILIT SEBAGAI VARIABEL-TRANSFORMATOR

Generally induction motor is used as a tool to change electric power to mechanic one. In forced condition wound-rotor induction motor can be used as transformer. This case can be accepted for both machines work by induction principle. Stator is the primary side of a three phase-tra...

全面介紹

Saved in:
書目詳細資料
Main Authors: Subekti, Lukman, Budiyanto, Ma'un
格式: Article PeerReviewed
語言:English
出版: Jurusan Teknik Informatika Fakultas Teknologi Industri UPN "Veteran" Jogjakarta 2009
主題:
在線閱讀:https://repository.ugm.ac.id/35942/1/4_Unjuk_Kerja_Motor_Induksi_Rotor_Lilit_Sebagai_Variabel-Transformator.pdf
https://repository.ugm.ac.id/35942/
標簽: 添加標簽
沒有標簽, 成為第一個標記此記錄!
id id-ugm-repo.35942
record_format dspace
spelling id-ugm-repo.359422014-04-29T04:41:20Z https://repository.ugm.ac.id/35942/ UNJUK KERJA MOTOR INDUKSI ROTOR LILIT SEBAGAI VARIABEL-TRANSFORMATOR Subekti, Lukman Budiyanto, Ma'un Makalah prosiding Generally induction motor is used as a tool to change electric power to mechanic one. In forced condition wound-rotor induction motor can be used as transformer. This case can be accepted for both machines work by induction principle. Stator is the primary side of a three phase-transformer. Magnetic field produced by stator cuts across rotor conduction. This induction voltage cases the rotor current to flow. However, induction motor is one of non-linear load and be able to cause harmonic in alternating current. The objective of this research is to acknowledge the work of wound-rotor induction motor when its function is changed into a transformer. The research was done by the wound rotor supplied sinusoidal voltage as the primary of a three phase transformer. The magnetic filed produced by rotor cuts across stator conductor. Rotor position was regulated from 0 degree,45 degree, 90 degree, 135, up to 360 degree. In stator winding, the amount of emf induced proportional to the rate of flux change and the number of its wound. The result of research shows that wound-rotor induction motor can be used as variable transformer. Voltage change obtained is about 8%. Voltage waved) form isdefect sinusoidal. The average value of Total Harmonic Distortion (THD) is 1.8% for displacement of rotor angle from 0 degree up to 360 degree Jurusan Teknik Informatika Fakultas Teknologi Industri UPN "Veteran" Jogjakarta 2009-05-23 Article PeerReviewed application/pdf en https://repository.ugm.ac.id/35942/1/4_Unjuk_Kerja_Motor_Induksi_Rotor_Lilit_Sebagai_Variabel-Transformator.pdf Subekti, Lukman and Budiyanto, Ma'un (2009) UNJUK KERJA MOTOR INDUKSI ROTOR LILIT SEBAGAI VARIABEL-TRANSFORMATOR. Prosiding Seminar Nasional Teknik Informatika e-Democracy : “ Dukungan e-Democracy dalam Meningkatkan Mutu Demokrasi di Indonesia”, di Jurusan Teknik Informatika Fakultas Teknologi Industri UPN "Veteran" Jogjakarta. B-58-B-66. ISSN 1979-2328
institution Universitas Gadjah Mada
building UGM Library
country Indonesia
collection Repository Civitas UGM
language English
topic Makalah prosiding
spellingShingle Makalah prosiding
Subekti, Lukman
Budiyanto, Ma'un
UNJUK KERJA MOTOR INDUKSI ROTOR LILIT SEBAGAI VARIABEL-TRANSFORMATOR
description Generally induction motor is used as a tool to change electric power to mechanic one. In forced condition wound-rotor induction motor can be used as transformer. This case can be accepted for both machines work by induction principle. Stator is the primary side of a three phase-transformer. Magnetic field produced by stator cuts across rotor conduction. This induction voltage cases the rotor current to flow. However, induction motor is one of non-linear load and be able to cause harmonic in alternating current. The objective of this research is to acknowledge the work of wound-rotor induction motor when its function is changed into a transformer. The research was done by the wound rotor supplied sinusoidal voltage as the primary of a three phase transformer. The magnetic filed produced by rotor cuts across stator conductor. Rotor position was regulated from 0 degree,45 degree, 90 degree, 135, up to 360 degree. In stator winding, the amount of emf induced proportional to the rate of flux change and the number of its wound. The result of research shows that wound-rotor induction motor can be used as variable transformer. Voltage change obtained is about 8%. Voltage waved) form isdefect sinusoidal. The average value of Total Harmonic Distortion (THD) is 1.8% for displacement of rotor angle from 0 degree up to 360 degree
format Article
PeerReviewed
author Subekti, Lukman
Budiyanto, Ma'un
author_facet Subekti, Lukman
Budiyanto, Ma'un
author_sort Subekti, Lukman
title UNJUK KERJA MOTOR INDUKSI ROTOR LILIT SEBAGAI VARIABEL-TRANSFORMATOR
title_short UNJUK KERJA MOTOR INDUKSI ROTOR LILIT SEBAGAI VARIABEL-TRANSFORMATOR
title_full UNJUK KERJA MOTOR INDUKSI ROTOR LILIT SEBAGAI VARIABEL-TRANSFORMATOR
title_fullStr UNJUK KERJA MOTOR INDUKSI ROTOR LILIT SEBAGAI VARIABEL-TRANSFORMATOR
title_full_unstemmed UNJUK KERJA MOTOR INDUKSI ROTOR LILIT SEBAGAI VARIABEL-TRANSFORMATOR
title_sort unjuk kerja motor induksi rotor lilit sebagai variabel-transformator
publisher Jurusan Teknik Informatika Fakultas Teknologi Industri UPN "Veteran" Jogjakarta
publishDate 2009
url https://repository.ugm.ac.id/35942/1/4_Unjuk_Kerja_Motor_Induksi_Rotor_Lilit_Sebagai_Variabel-Transformator.pdf
https://repository.ugm.ac.id/35942/
_version_ 1681219464590262272