Usefulness of Combining NT-proBNP Level and Right Atrial Diameter for Simple and Early Noninvasive Detection of Pulmonary Hypertension Among Adult Patients with Atrial Septal Defect

Background: Atrial septal defect developed pulmonary hypertension (ASD-PH) at first diagnosis due to late presentation are common in Indonesia. Transthoracic echocardiogram (TTE) is a common tool to detect ASD-PH, before proceeding to invasive procedure. The NT-proBNP measurement to screen ASD-PH is...

وصف كامل

محفوظ في:
التفاصيل البيبلوغرافية
المؤلفون الرئيسيون: Hartopo, Anggoro Budi, Anggrahini, Dyah Wulan, Satwiko, Muhammad G., Damarkusuma, Arditya, Pritazahra, Armalya, Hadwiono, Muhammad Reyhan, Dewanto, Vera C., Somma, Salvatore Di, Emoto, Noriaki, Dinarti, Lucia Kris
التنسيق: مقال PeerReviewed
اللغة:English
منشور في: Indonesian Society of Internal Medicine 2022
الموضوعات:
الوصول للمادة أونلاين:https://repository.ugm.ac.id/283287/1/34.pdf
https://repository.ugm.ac.id/283287/
https://www.scopus.com/inward/record.uri?eid=2-s2.0-85145957318&partnerID=40&md5=9eeace252a1debc2de722665c5493b2b
الوسوم: إضافة وسم
لا توجد وسوم, كن أول من يضع وسما على هذه التسجيلة!
الوصف
الملخص:Background: Atrial septal defect developed pulmonary hypertension (ASD-PH) at first diagnosis due to late presentation are common in Indonesia. Transthoracic echocardiogram (TTE) is a common tool to detect ASD-PH, before proceeding to invasive procedure. The NT-proBNP measurement to screen ASD-PH is not yet considered the standard approach, especially in limited resource conditions. The objective of this study is to assess the value of NT-proBNP, along with simple TTE parameter, to screen PH among adults with ASD. Methods: This was a cross-sectional study. The subjects were adult ASD-PH patients from the COHARD-PH registry (n=357). Right heart catheterization (RHC) was performed to diagnose PH. Blood sample was withdrawn during RHC for NT-proBNP measurement. The TTE was performed as standard procedure and its regular parameters were assessed, along with NT-proBNP, to detect PH. Results: Two parameters significantly predicted PH, namely NT-proBNP and right atrial (RA) diameter. The cut-off of NT-proBNP to detect PH was ≥140 pg/mL. The cut-off of RA diameter to detect PH was ≥46.0 mm. The combined values of NT-proBNP level ≥140 pg/mL and RA diameter ≥46.0 mm yielded 46.6 sensitivity, 91.8 specificity, 54.3 accuracy, 96.5 positive predictive value and 26.2 negative predictive value to detect PH, which were better than single value. Conclusion: NT-proBNP level ≥140 pg/mL represented PH in adult ASD patients. The NT-proBNP level ≥140 pg/mL and RA diameter ≥46.0 mm had a pre-test probability measures to triage patients needing more invasive procedure and also to determine when and if to start the PH-specific treatment. © 2022, Indonesian Society of Internal Medicine. All rights reserved.