Optimization Of Collimator Design For Bnct Based Cyclotron 30 Mev And Its Dosimetry Simulation In Head And Neck Soft Tissue Sarcoma Using Monte Carlo N Particle X Program

Abstract This article involves two main objectives for BNCT system. First goal includes optimization of cyclotron based BNCT collimator. Second goal is to calculate the neutron flux and dosimetry system of Boron Neutron Capture Therapy (BNCT) in head and neck soft tissue sarcoma (STS). A seri...

全面介紹

Saved in:
書目詳細資料
Main Authors: Ardana, I Made, Kusminarto, Kusminarto, Sardjono, Yohannes
格式: Conference or Workshop Item PeerReviewed
語言:English
出版: 2015
主題:
在線閱讀:https://repository.ugm.ac.id/139412/1/Made%20article%27s.pdf
https://repository.ugm.ac.id/139412/
標簽: 添加標簽
沒有標簽, 成為第一個標記此記錄!
機構: Universitas Gadjah Mada
語言: English
id id-ugm-repo.139412
record_format dspace
spelling id-ugm-repo.1394122017-02-16T03:23:00Z https://repository.ugm.ac.id/139412/ Optimization Of Collimator Design For Bnct Based Cyclotron 30 Mev And Its Dosimetry Simulation In Head And Neck Soft Tissue Sarcoma Using Monte Carlo N Particle X Program Ardana, I Made Kusminarto, Kusminarto Sardjono, Yohannes Nuclear Physics Abstract This article involves two main objectives for BNCT system. First goal includes optimization of cyclotron based BNCT collimator. Second goal is to calculate the neutron flux and dosimetry system of Boron Neutron Capture Therapy (BNCT) in head and neck soft tissue sarcoma (STS). A series of simulations has been carried out using a Monte Carlo N Particle X program to find out the final composition and configuration of a collimator to moderate the fast neutron flux which is generated from the thick beryllium target. The final configuration for collimator design included 39 cm aluminium as moderator, 8.2 cm lithium fluoride as fast neutron filter and 0.5 cm boron carbide as thermal neutron filter. Bismuth, lead fluoride, and lead were chosen as the aperture, reflector, and gamma shielding, respectively. Epithermal neutron fluxes in the suggested design were 2.83E9 n/cm2 s, while other IAEA parameters for BNCT collimator design had been satisfied. In the next step, it was simulated its dosimetry for head and neck soft tissue sarcoma. Simulations carried out by varying the concentration of boron compounds in ORNL neck phantom model to obtained the optimal dosimetry results. MCNPX calculation showed that the optimal depth for thermal neutron was 4.8 cm in tissue phantom with the maximum dose rate was in GTV on each boron concentration variation respectively. The irradiated time needed for this therapy for each variables respectively less than an hour. 2015-10-26 Conference or Workshop Item PeerReviewed application/pdf en https://repository.ugm.ac.id/139412/1/Made%20article%27s.pdf Ardana, I Made and Kusminarto, Kusminarto and Sardjono, Yohannes (2015) Optimization Of Collimator Design For Bnct Based Cyclotron 30 Mev And Its Dosimetry Simulation In Head And Neck Soft Tissue Sarcoma Using Monte Carlo N Particle X Program. In: International symposium on BNCT: The Application of Nuclear Technology to Support National Sustainable Development: Health, Agriculture, Energy, Industry and Environment, 26-28 October 2015, UKSW Salatiga, Indonesia.
institution Universitas Gadjah Mada
building UGM Library
country Indonesia
collection Repository Civitas UGM
language English
topic Nuclear Physics
spellingShingle Nuclear Physics
Ardana, I Made
Kusminarto, Kusminarto
Sardjono, Yohannes
Optimization Of Collimator Design For Bnct Based Cyclotron 30 Mev And Its Dosimetry Simulation In Head And Neck Soft Tissue Sarcoma Using Monte Carlo N Particle X Program
description Abstract This article involves two main objectives for BNCT system. First goal includes optimization of cyclotron based BNCT collimator. Second goal is to calculate the neutron flux and dosimetry system of Boron Neutron Capture Therapy (BNCT) in head and neck soft tissue sarcoma (STS). A series of simulations has been carried out using a Monte Carlo N Particle X program to find out the final composition and configuration of a collimator to moderate the fast neutron flux which is generated from the thick beryllium target. The final configuration for collimator design included 39 cm aluminium as moderator, 8.2 cm lithium fluoride as fast neutron filter and 0.5 cm boron carbide as thermal neutron filter. Bismuth, lead fluoride, and lead were chosen as the aperture, reflector, and gamma shielding, respectively. Epithermal neutron fluxes in the suggested design were 2.83E9 n/cm2 s, while other IAEA parameters for BNCT collimator design had been satisfied. In the next step, it was simulated its dosimetry for head and neck soft tissue sarcoma. Simulations carried out by varying the concentration of boron compounds in ORNL neck phantom model to obtained the optimal dosimetry results. MCNPX calculation showed that the optimal depth for thermal neutron was 4.8 cm in tissue phantom with the maximum dose rate was in GTV on each boron concentration variation respectively. The irradiated time needed for this therapy for each variables respectively less than an hour.
format Conference or Workshop Item
PeerReviewed
author Ardana, I Made
Kusminarto, Kusminarto
Sardjono, Yohannes
author_facet Ardana, I Made
Kusminarto, Kusminarto
Sardjono, Yohannes
author_sort Ardana, I Made
title Optimization Of Collimator Design For Bnct Based Cyclotron 30 Mev And Its Dosimetry Simulation In Head And Neck Soft Tissue Sarcoma Using Monte Carlo N Particle X Program
title_short Optimization Of Collimator Design For Bnct Based Cyclotron 30 Mev And Its Dosimetry Simulation In Head And Neck Soft Tissue Sarcoma Using Monte Carlo N Particle X Program
title_full Optimization Of Collimator Design For Bnct Based Cyclotron 30 Mev And Its Dosimetry Simulation In Head And Neck Soft Tissue Sarcoma Using Monte Carlo N Particle X Program
title_fullStr Optimization Of Collimator Design For Bnct Based Cyclotron 30 Mev And Its Dosimetry Simulation In Head And Neck Soft Tissue Sarcoma Using Monte Carlo N Particle X Program
title_full_unstemmed Optimization Of Collimator Design For Bnct Based Cyclotron 30 Mev And Its Dosimetry Simulation In Head And Neck Soft Tissue Sarcoma Using Monte Carlo N Particle X Program
title_sort optimization of collimator design for bnct based cyclotron 30 mev and its dosimetry simulation in head and neck soft tissue sarcoma using monte carlo n particle x program
publishDate 2015
url https://repository.ugm.ac.id/139412/1/Made%20article%27s.pdf
https://repository.ugm.ac.id/139412/
_version_ 1681234230110060544