ANALISIS PERFORMA MODEL ORGANIC RANKINE CYCLE (ORC) PADA PT. GEO DIPA ENERGI Ltd. DIENG DENGAN VARIASI MEDIUM KERJA

Geothermal is one of the promising renewable energy sources which needs a large amount of capital cost, therefore it has to meet the thermo-economy efficiency. Thermo-economy efficiency could be achieved by making use all of the possible potencies that geothermal source has. Brine as the product of...

وصف كامل

محفوظ في:
التفاصيل البيبلوغرافية
المؤلفون الرئيسيون: , ADIATIE SUCININGTYAS, , Dr.-Ing. Sihana
التنسيق: Theses and Dissertations NonPeerReviewed
منشور في: [Yogyakarta] : Universitas Gadjah Mada 2014
الموضوعات:
ETD
الوصول للمادة أونلاين:https://repository.ugm.ac.id/132292/
http://etd.ugm.ac.id/index.php?mod=penelitian_detail&sub=PenelitianDetail&act=view&typ=html&buku_id=72819
الوسوم: إضافة وسم
لا توجد وسوم, كن أول من يضع وسما على هذه التسجيلة!
المؤسسة: Universitas Gadjah Mada
id id-ugm-repo.132292
record_format dspace
spelling id-ugm-repo.1322922016-03-04T07:51:34Z https://repository.ugm.ac.id/132292/ ANALISIS PERFORMA MODEL ORGANIC RANKINE CYCLE (ORC) PADA PT. GEO DIPA ENERGI Ltd. DIENG DENGAN VARIASI MEDIUM KERJA , ADIATIE SUCININGTYAS , Dr.-Ing. Sihana ETD Geothermal is one of the promising renewable energy sources which needs a large amount of capital cost, therefore it has to meet the thermo-economy efficiency. Thermo-economy efficiency could be achieved by making use all of the possible potencies that geothermal source has. Brine as the product of separation process of two phase geothermal wells and geothermal wells that have low to moderate temperature are some of the examples of the possible candidate. Those type of wells could be exploited by Organic Rankine Cycle (ORC) power generation. This study is intended to obtain optimum condition of each system with different working fluid and comparing the results to pick out the best performance. The chosen refrigerants are R124, R290, R152a. Comparison will be done by considering system efficiency, their power output, environmentaly friendly properties, and heating area needed for the heat exchanger component. The best performance is delivered by system with refrigerant R124 as working fluid, which generates1657.61 kWpower with 8.99% efficiency. It also needs the least heating area as much as 2640.48 m2on the heat-adding component and 353.51 m2on the heat-rejecting component. Refrigerant R290 is the worst working fluid to be applied on the system because it has the lowest efficiency while refrigerant R152a place second-best but need a lot of superheating process. [Yogyakarta] : Universitas Gadjah Mada 2014 Thesis NonPeerReviewed , ADIATIE SUCININGTYAS and , Dr.-Ing. Sihana (2014) ANALISIS PERFORMA MODEL ORGANIC RANKINE CYCLE (ORC) PADA PT. GEO DIPA ENERGI Ltd. DIENG DENGAN VARIASI MEDIUM KERJA. UNSPECIFIED thesis, UNSPECIFIED. http://etd.ugm.ac.id/index.php?mod=penelitian_detail&sub=PenelitianDetail&act=view&typ=html&buku_id=72819
institution Universitas Gadjah Mada
building UGM Library
country Indonesia
collection Repository Civitas UGM
topic ETD
spellingShingle ETD
, ADIATIE SUCININGTYAS
, Dr.-Ing. Sihana
ANALISIS PERFORMA MODEL ORGANIC RANKINE CYCLE (ORC) PADA PT. GEO DIPA ENERGI Ltd. DIENG DENGAN VARIASI MEDIUM KERJA
description Geothermal is one of the promising renewable energy sources which needs a large amount of capital cost, therefore it has to meet the thermo-economy efficiency. Thermo-economy efficiency could be achieved by making use all of the possible potencies that geothermal source has. Brine as the product of separation process of two phase geothermal wells and geothermal wells that have low to moderate temperature are some of the examples of the possible candidate. Those type of wells could be exploited by Organic Rankine Cycle (ORC) power generation. This study is intended to obtain optimum condition of each system with different working fluid and comparing the results to pick out the best performance. The chosen refrigerants are R124, R290, R152a. Comparison will be done by considering system efficiency, their power output, environmentaly friendly properties, and heating area needed for the heat exchanger component. The best performance is delivered by system with refrigerant R124 as working fluid, which generates1657.61 kWpower with 8.99% efficiency. It also needs the least heating area as much as 2640.48 m2on the heat-adding component and 353.51 m2on the heat-rejecting component. Refrigerant R290 is the worst working fluid to be applied on the system because it has the lowest efficiency while refrigerant R152a place second-best but need a lot of superheating process.
format Theses and Dissertations
NonPeerReviewed
author , ADIATIE SUCININGTYAS
, Dr.-Ing. Sihana
author_facet , ADIATIE SUCININGTYAS
, Dr.-Ing. Sihana
author_sort , ADIATIE SUCININGTYAS
title ANALISIS PERFORMA MODEL ORGANIC RANKINE CYCLE (ORC) PADA PT. GEO DIPA ENERGI Ltd. DIENG DENGAN VARIASI MEDIUM KERJA
title_short ANALISIS PERFORMA MODEL ORGANIC RANKINE CYCLE (ORC) PADA PT. GEO DIPA ENERGI Ltd. DIENG DENGAN VARIASI MEDIUM KERJA
title_full ANALISIS PERFORMA MODEL ORGANIC RANKINE CYCLE (ORC) PADA PT. GEO DIPA ENERGI Ltd. DIENG DENGAN VARIASI MEDIUM KERJA
title_fullStr ANALISIS PERFORMA MODEL ORGANIC RANKINE CYCLE (ORC) PADA PT. GEO DIPA ENERGI Ltd. DIENG DENGAN VARIASI MEDIUM KERJA
title_full_unstemmed ANALISIS PERFORMA MODEL ORGANIC RANKINE CYCLE (ORC) PADA PT. GEO DIPA ENERGI Ltd. DIENG DENGAN VARIASI MEDIUM KERJA
title_sort analisis performa model organic rankine cycle (orc) pada pt. geo dipa energi ltd. dieng dengan variasi medium kerja
publisher [Yogyakarta] : Universitas Gadjah Mada
publishDate 2014
url https://repository.ugm.ac.id/132292/
http://etd.ugm.ac.id/index.php?mod=penelitian_detail&sub=PenelitianDetail&act=view&typ=html&buku_id=72819
_version_ 1681233476501635072