การออกแบบปรับปรุงความเร็วลมเพื่อภาวะน่าสบายใต้ถุนอาคารสูง

166 pages

Saved in:
Bibliographic Details
Main Author: ณรงค์ชัย ประเสริฐศักดา
Other Authors: ธนิต จินดาวณิค
Format: Theses and Dissertations
Language:Thai
Published: จุฬาลงกรณ์มหาวิทยาลัย 2007
Subjects:
Online Access:https://digiverse.chula.ac.th/Info/item/dc:53174
Tags: Add Tag
No Tags, Be the first to tag this record!
Institution: Chulalongkorn University
Language: Thai
id 53174
record_format dspace
institution Chulalongkorn University
building Chulalongkorn University Library
continent Asia
country Thailand
Thailand
content_provider Chulalongkorn University Library
collection Chulalongkorn University Intellectual Repository
language Thai
topic ลม -- ความเร็ว -- การออกแบบ
ลมกับสถาปัตยกรรม
อาคารสูง
ภาวะสบาย
Winds -- Speed -- Design
Winds and architecture
Tall buildings
Human comfort
spellingShingle ลม -- ความเร็ว -- การออกแบบ
ลมกับสถาปัตยกรรม
อาคารสูง
ภาวะสบาย
Winds -- Speed -- Design
Winds and architecture
Tall buildings
Human comfort
ณรงค์ชัย ประเสริฐศักดา
การออกแบบปรับปรุงความเร็วลมเพื่อภาวะน่าสบายใต้ถุนอาคารสูง
description 166 pages
author2 ธนิต จินดาวณิค
author_facet ธนิต จินดาวณิค
ณรงค์ชัย ประเสริฐศักดา
format Theses and Dissertations
author ณรงค์ชัย ประเสริฐศักดา
author_sort ณรงค์ชัย ประเสริฐศักดา
title การออกแบบปรับปรุงความเร็วลมเพื่อภาวะน่าสบายใต้ถุนอาคารสูง
title_short การออกแบบปรับปรุงความเร็วลมเพื่อภาวะน่าสบายใต้ถุนอาคารสูง
title_full การออกแบบปรับปรุงความเร็วลมเพื่อภาวะน่าสบายใต้ถุนอาคารสูง
title_fullStr การออกแบบปรับปรุงความเร็วลมเพื่อภาวะน่าสบายใต้ถุนอาคารสูง
title_full_unstemmed การออกแบบปรับปรุงความเร็วลมเพื่อภาวะน่าสบายใต้ถุนอาคารสูง
title_sort การออกแบบปรับปรุงความเร็วลมเพื่อภาวะน่าสบายใต้ถุนอาคารสูง
publisher จุฬาลงกรณ์มหาวิทยาลัย
publishDate 2007
url https://digiverse.chula.ac.th/Info/item/dc:53174
_version_ 1829271778394898432
spelling 531742024-03-19T13:25:50Z https://digiverse.chula.ac.th/Info/item/dc:53174 ©จุฬาลงกรณ์มหาวิทยาลัย Thesis 10.58837/CHULA.THE.2007.1777 tha ณรงค์ชัย ประเสริฐศักดา การออกแบบปรับปรุงความเร็วลมเพื่อภาวะน่าสบายใต้ถุนอาคารสูง Design for wind speed improvement in open space underneath tall building จุฬาลงกรณ์มหาวิทยาลัย 2007 2007 166 pages To investigate the effects of wind speed underneath tall buildings, the effects of wind speed on a comfort zone and a design creating a comfort zone through natural ventilation. The study was conducted by collecting data on wind speed and wind directions of open space underneath the tall buildings in Chulalongkorn University. According to the data analysis, the rate of wind speed underneath buildings of more than 6 stories was higher than the standard rate of wind speed creating a comfort zone (3.0 m/s). This causes problems to those working in such areas and light material can be blown away. Building models were constructed at the aspect ratio of 1:1, 1:2, 1:3 and 1:4. These models were of different stories: 4 stories, 8 stories, 12 stories, 16 stories and 20 stories. Computational fluid dynamics (CFD) analysis was used to analyze the effects of average wind speed creating a comfort zone. This average wind speed at 1.7 m/s is determined by the Bangkok weather data. It was found that the average wind speed underneath the buildings of more than 6 stories was higher than standard wind speed for creating a comfort zone. The building with the aspect ratio of 1:2 posed a lot of problems. The obtained results led to 4 designs to control wind direction and wind speed. The 4 designs were 1) using a one-sided windbreaker along the length of the building, 2) using a two-sided windbreaker, 3) using a row of trees with the density of 50% and 4) improving the landscape. When the two-sided windbreaker and a row of trees were used with the building with the ratio of 1:2, the wind speed could be reduced by 43%. It can be concluded that a building of 6-10 stories should be equipped with a two-sided windbreaker. In this case the windbreaker should be as the height of the open space underneath the building. As for a building of 12 stories, a row of trees and a two-sided windbreaker which is as wide as the height of the open space underneath the building are required. A building of more than 12 stories should be equipped with a two-sided windbreaker, two rows of trees planted away from the building within the range of 1.5 times of the height of the building. These two rows of trees should be planted alternately. ศึกษาผลกระทบของกระแสลมต่อผู้ใช้พื้นที่ใต้ถุนอาคารสูง ปัญหาของกระแสลมต่อสภาวะน่าสบาย และสร้างแนวทางการออกแบบให้เกิดสภาวะน่าสบายในการระบายอากาศโดยวิธีธรรมชาติ สำหรับพื้นที่ใต้ถุนอาคาร การศึกษาดำเนินการโดยเก็บข้อมูลความเร็วลมและทิศทางของกระแสลม จากพื้นที่อาคารกรณีศึกษาในจุฬาลงกรณ์มหาวิทยาลัย จากนั้นวิเคราะห์ข้อมูลความเร็วลมในพื้นที่ใต้ถุนอาคารกรณีศึกษา ซึ่งพบว่าอาคารที่มีความสูงมากกว่า 6 ชั้น มีค่าความเร็วลมมากกว่าสภาวะน่าสบายที่กำหนดไว้ 3.0 m/s ซึ่งรบกวนการใช้งานและทำให้วัสดุที่มีน้ำหนักเบาเริ่มปลิว จากการศึกษาอาคารกรณีศึกษาแล้วได้นำมาสร้างเป็นอาคารจำลองในสัดส่วนอาคาร 1:1, 1:2, 1:3 และ 1:4 ในระดับความสูง 4 ชั้น 8 ชั้น 12 ชั้น และ 20 ชั้น และใช้โปรแกรม Computation Fluid Dynamic หรือ CFD ซึ่งศึกษาผลกระทบต่อผู้ใช้พื้นที่ใต้ถุนอาคารสูงโดยใช้ความเร็วลมเฉลี่ยของกรุงเทพมหานครที่ 1.7 m/s จากการจำลองสภาพดังกล่าวค่าความเร็วลมเฉลี่ยในพื้นที่ใต้ถุนอาคารที่มีความสูงตั้งแต่ 6 ชั้น มีค่าความเร็วลมมากกว่าสภาวะน่าสบายที่กำหนด และอาคารที่มีปัญหามากที่สุดคืออาคารที่มีสัดส่วน 1:2 จากข้อมูลดังกล่าวได้นำไปศึกษาแนวทางการออกแบบ 4 แนวทางคือ การใช้แผงดักลม 1 ด้าน และ 2 ด้าน ที่ขนานกับอาคารตามแนวยาวเพื่อควบคุมทิศทางและความเร็วลม การใช้แนวต้นไม้ที่มีความหนาแน่น 50% และการปรับปรุงภูมิทัศน์ จากการจำลองสภาพกับอาคารจำลองสัดส่วน 1:2 ทำให้ทราบว่าอาคารการใช้แผงดักลมร่วมกับแนวต้นไม้ มีประสิทธิภาพในการลดความเร็วลมมากที่สุดคือ 43% จากผลการศึกษาสามารถสร้างแนวทางในการออกแบบดังนี้ อาคารที่มีความสูงตั้งแต่ 6-10 ชั้น ควรติดตั้งแผงดักลมความกว้าง 1 เท่าของความสูงพื้นที่ใต้ถุนอาคารทั้ง 2 ด้าน ขนานตามแนวยาวเพื่อปรับให้กระแสลมอยู่ในสภาวะน่าสบาย อาคารสูง 12 ชั้น จำเป็นต้องใช้แนวต้นไม้ที่ความหนาแน่น 50% เพื่อชะลอความเร็วลมร่วมกับแผงดักลมกว้าง 1 เท่า ของความสูงพื้นที่ใตถุนอาคารและอาคารความสูงมากกว่า 12 ชั้นควรติดตั้งแผงดักลมทั้ง 2 ด้าน ขนานตลอดแนวอาคารเพื่อควบคุมทิศทางและกระแสลมในพื้นที่ใต้ถุนอาคาร โดยสร้างแนวต้นไม้ที่มีระยะห่างจากอาคารไม่เกิน 1.5 เท่าของความสูงใต้ถุนอาคาร และควรสร้างแนวต้นไม้ 2 แนวสลับแถวเพื่อลดความเร็วลมให้มีประสิทธิภาพมากขึ้น ลม -- ความเร็ว -- การออกแบบ ลมกับสถาปัตยกรรม อาคารสูง ภาวะสบาย Winds -- Speed -- Design Winds and architecture Tall buildings Human comfort ธนิต จินดาวณิค อรรจน์ เศรษฐบุตร https://digiverse.chula.ac.th/digital/file_upload/biblio/cover/53174.jpg