Effect of direct electric resistance heat treatment on mechanical properties of NiTi orthodontic arch wires

Two types of rectangular orthodontic archwires; NiTi™ and 40°CuNiTi, were heat treated by Direct Electric Resistance Heat Treatment (DERHT) using different electric currents for 4 s. Their mechanical properties were then evaluated by micro hardness and three-point bending tests. After applying 4.5-5...