Sistem Kendali Daya Aktif untuk Inverter Satu Fase yang Terintegrasi dengan Jaringan Distribusi 220 Vrms

Distributed generation (DG) are under increasing concern for fulfill future electricity needs. One type of DG is solar power plants (PLTS). The problems that arise in trying to integrate PLTS into the power grid is how to control the power flow to the grid. This research aims to simulate the ac...

وصف كامل

محفوظ في:
التفاصيل البيبلوغرافية
المؤلفون الرئيسيون: Wijaya, Fransisco Danang, Sidik, Yohan Fajar, Firmansyah, Eka
التنسيق: Conference or Workshop Item PeerReviewed
اللغة:English
منشور في: 2012
الموضوعات:
الوصول للمادة أونلاين:https://repository.ugm.ac.id/273735/1/Sistem%20Kendali%20Daya%20Aktif%20Untuk%20Inverter%20Satu%20Fase.pdf
https://repository.ugm.ac.id/273735/
http://citee.te.ugm.ac.id/
الوسوم: إضافة وسم
لا توجد وسوم, كن أول من يضع وسما على هذه التسجيلة!
id id-ugm-repo.273735
record_format dspace
spelling id-ugm-repo.2737352017-11-06T08:32:04Z https://repository.ugm.ac.id/273735/ Sistem Kendali Daya Aktif untuk Inverter Satu Fase yang Terintegrasi dengan Jaringan Distribusi 220 Vrms Wijaya, Fransisco Danang Sidik, Yohan Fajar Firmansyah, Eka Electrical and Electronic Engineering Distributed generation (DG) are under increasing concern for fulfill future electricity needs. One type of DG is solar power plants (PLTS). The problems that arise in trying to integrate PLTS into the power grid is how to control the power flow to the grid. This research aims to simulate the active power control system for single-phase inverter. This control system can adjust the power generated by the inverter to be given to the local load. If there is excess of power supply, the power is supplied to the grid. The proposed control system is based on dq transformation. Angular frequency as a reference for dq transformation algorithm derived from phase locked loop (PLL)-based transport delay T / 4. Control actions carried out by the current control proportional integrator (PI). Control system is assessed through the ability to send the parameters of active power and total harmonic distortion index (THD) inverter current is low. The simulation results show that the inverter can be controlled to provide active power to the local load. However, it was found that the non-linear conditions on the grid can reduce the quality of the inverter currents. 2012-07-12 Conference or Workshop Item PeerReviewed application/pdf en https://repository.ugm.ac.id/273735/1/Sistem%20Kendali%20Daya%20Aktif%20Untuk%20Inverter%20Satu%20Fase.pdf Wijaya, Fransisco Danang and Sidik, Yohan Fajar and Firmansyah, Eka (2012) Sistem Kendali Daya Aktif untuk Inverter Satu Fase yang Terintegrasi dengan Jaringan Distribusi 220 Vrms. In: Conference on Information Technology and Electrical Engineering (CITEE) 2012, 12 July 2012, Yogyakarta, Indonesia. http://citee.te.ugm.ac.id/
institution Universitas Gadjah Mada
building UGM Library
country Indonesia
collection Repository Civitas UGM
language English
topic Electrical and Electronic Engineering
spellingShingle Electrical and Electronic Engineering
Wijaya, Fransisco Danang
Sidik, Yohan Fajar
Firmansyah, Eka
Sistem Kendali Daya Aktif untuk Inverter Satu Fase yang Terintegrasi dengan Jaringan Distribusi 220 Vrms
description Distributed generation (DG) are under increasing concern for fulfill future electricity needs. One type of DG is solar power plants (PLTS). The problems that arise in trying to integrate PLTS into the power grid is how to control the power flow to the grid. This research aims to simulate the active power control system for single-phase inverter. This control system can adjust the power generated by the inverter to be given to the local load. If there is excess of power supply, the power is supplied to the grid. The proposed control system is based on dq transformation. Angular frequency as a reference for dq transformation algorithm derived from phase locked loop (PLL)-based transport delay T / 4. Control actions carried out by the current control proportional integrator (PI). Control system is assessed through the ability to send the parameters of active power and total harmonic distortion index (THD) inverter current is low. The simulation results show that the inverter can be controlled to provide active power to the local load. However, it was found that the non-linear conditions on the grid can reduce the quality of the inverter currents.
format Conference or Workshop Item
PeerReviewed
author Wijaya, Fransisco Danang
Sidik, Yohan Fajar
Firmansyah, Eka
author_facet Wijaya, Fransisco Danang
Sidik, Yohan Fajar
Firmansyah, Eka
author_sort Wijaya, Fransisco Danang
title Sistem Kendali Daya Aktif untuk Inverter Satu Fase yang Terintegrasi dengan Jaringan Distribusi 220 Vrms
title_short Sistem Kendali Daya Aktif untuk Inverter Satu Fase yang Terintegrasi dengan Jaringan Distribusi 220 Vrms
title_full Sistem Kendali Daya Aktif untuk Inverter Satu Fase yang Terintegrasi dengan Jaringan Distribusi 220 Vrms
title_fullStr Sistem Kendali Daya Aktif untuk Inverter Satu Fase yang Terintegrasi dengan Jaringan Distribusi 220 Vrms
title_full_unstemmed Sistem Kendali Daya Aktif untuk Inverter Satu Fase yang Terintegrasi dengan Jaringan Distribusi 220 Vrms
title_sort sistem kendali daya aktif untuk inverter satu fase yang terintegrasi dengan jaringan distribusi 220 vrms
publishDate 2012
url https://repository.ugm.ac.id/273735/1/Sistem%20Kendali%20Daya%20Aktif%20Untuk%20Inverter%20Satu%20Fase.pdf
https://repository.ugm.ac.id/273735/
http://citee.te.ugm.ac.id/
_version_ 1681234345792110592