Koefisien perpindahan massa keseluruhan volumetris pada kolom ekstraksi mixer-settler
BSTRAK The volumetric over-all mass transfer coefficient (K,.a) in a single stage mixer-settler column has been investigated. In the measurement of K,.a. acetic acid was extracted from kerosene-acetic acid solution into water. The mixer-settler column used in this experiment was divided into a mixer...
محفوظ في:
المؤلف الرئيسي: | |
---|---|
التنسيق: | مقال NonPeerReviewed |
منشور في: |
[Yogyakarta] : Badan Kerjasama Penelitian dan Pengembangan Pariwisata
2002
|
الموضوعات: | |
الوصول للمادة أونلاين: | https://repository.ugm.ac.id/26728/ http://i-lib.ugm.ac.id/jurnal/download.php?dataId=9769 |
الوسوم: |
إضافة وسم
لا توجد وسوم, كن أول من يضع وسما على هذه التسجيلة!
|
الملخص: | BSTRAK
The volumetric over-all mass transfer coefficient (K,.a) in a single stage mixer-settler column has been investigated.
In the measurement of K,.a. acetic acid was extracted from kerosene-acetic acid solution into water. The mixer-settler column used in this experiment was divided into a mixer of 5.8 em height and a settler of 5.5 em height separated by a drop coalescer. The column diameter was 10.2 em. The diameter of drop coalescer was 5 em. I em in height. with the holes diameter of I mm. The values of K,.a were affected by the volumetric rates of the continuous and dispersed phases and also by agitation speed. These data can be correlated by Sh,. = 8.75 X /0,/11 Re.o.3/ Relf>2 Re/46 in the ranges of ReI' of 149.18358.63. Red of 51.18-296.91. and Rei of 5.639.12-11.280.06 with the relative mean error of 11.32%.
Keywords: volumetris, kolom ekstraksi, Mixer-Settler |
---|