KORELASI pH DENGAN KADAR LDH PADA TROMBOSIT KONSENTRAT DALAM BERBAGAI WAKTU PENGOLAHAN SELAMA MASA PENYIMPANAN
BACKGROUND : Quality control of thrombocyte concentrate is performed in purpose to know the profile of Platelet Storage Lession (PSL) during the storage. One of the PSL�s parameters are pH and LDH level. Both are directly involved in metabolisme of thrombocyte to produce energy. The significance d...
Saved in:
Main Authors: | , |
---|---|
格式: | Theses and Dissertations NonPeerReviewed |
出版: |
[Yogyakarta] : Universitas Gadjah Mada
2014
|
主題: | |
在線閱讀: | https://repository.ugm.ac.id/128106/ http://etd.ugm.ac.id/index.php?mod=penelitian_detail&sub=PenelitianDetail&act=view&typ=html&buku_id=68437 |
標簽: |
添加標簽
沒有標簽, 成為第一個標記此記錄!
|
總結: | BACKGROUND :
Quality control of thrombocyte concentrate is
performed in purpose to know the profile of Platelet
Storage Lession (PSL) during the storage. One of the
PSL�s parameters are pH and LDH level. Both are
directly involved in metabolisme of thrombocyte to
produce energy. The significance declined of pH value
and the significance increased of LDH level can effect
the quality of thrombocyte concentrates.
OBJECTIVES :
To know the correlation between pH value and LDH
level on thrombocyte concentrates during the storage
that processed on 0 hours, 6 hours, and 16 hours.
METHODS :
This research used observational method with
cross-sectional research design which was performed in
RSUP Dr Sardjito. The research samples were 15 of
thrombocyte concentrate bags. Then, sample divided into
3 categories (group 1 which is processed on 0 hour,
group 2 which is processed on 6 hours, and group 3
which is processed on 16 hours), and the value of pH
and level of LDH were measured using Blood Gas Analyzer
and Chemistry Analyzer respectively during storage on
day 0, day 1, day 3, and day 6. The result were
analyzed using Pearson Correlation Method.
RESULTS:
The results showed a significant correlation
between pH value and LDH level on thrombocyte
concentrate of group 1 (r:-0,52 |
---|